{"id":3176,"date":"2023-11-22T16:58:38","date_gmt":"2023-11-22T16:58:38","guid":{"rendered":"https:\/\/firefocus.it\/non-categorizzato\/le-barriere-lineari-di-fumo-in-un-sistema-indirizzato-meglio-alimentate-sul-loop-oppure-in-24v\/"},"modified":"2024-04-04T12:05:39","modified_gmt":"2024-04-04T12:05:39","slug":"the-linear-smoke-barriers-in-a-addressed-system-better-fed-on-the-loop-or-in-24v","status":"publish","type":"post","link":"https:\/\/firefocus.it\/en\/non-categorizzato\/the-linear-smoke-barriers-in-a-addressed-system-better-fed-on-the-loop-or-in-24v\/","title":{"rendered":"The linear smoke barriers in a addressed system: better fed on the loop or in 24V?"},"content":{"rendered":"<section class=\"gb-container gb-container-853708f6 container\">\n\n<h2 class=\"gb-headline gb-headline-e0218092 gb-headline-text\"><strong>The issue of the use of linear barriers within a fire smoke detection system has always been controversial: between those who claim to install a barrier on a loop and those who instead supply 24V, we try to clarify and give a definitive answer to avoid committing inaccuracies in the construction of a system.<\/strong><\/h2>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-6aeefb2d gb-headline-text\">Technological evolution in the firefighting world has led to the advent of linear barriers that integrate directly on the loops of the plant, from which they also draw the 24V power supply.<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-dc8feee8 gb-headline-text\">This new type of barrier could seem to be the best solution in terms of economic convenience and time savings in the execution of the system: in fact, just the loop cable is enough to have both the signals and the power supply.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"gb-headline gb-headline-f6864fac gb-headline-text\"><strong><strong><strong>However, it&#8217;s not as simple as that.<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-5f214f53 gb-headline-text\">In fact, a choice made based on economic savings does not take into account real installation factors so a loop barrier can never function correctly.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-1c86f378 gb-headline-text\">Let&#8217;s understand why.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">As we have said, the linear barrier is powered by loops, simplifying the work from the point of view of power, cables, etc..<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So far, everything is fine, but one fundamental aspect must be taken into account, otherwise there will be problems with the system!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What must be considered when using a linear barrier powered on the loop is that it must be correctly dimensioned to be able to withstand the electrical load of all the components managed.&nbsp;<\/p>\n\n\n\n<p class=\"gb-headline gb-headline-c2828fc5 gb-headline-text\"><strong><strong>Otherwise, the loop will fail, generating a disruption.<\/strong><\/strong><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-71d8e8b8 gb-headline-text\">As if that were not enough, it is also necessary to <strong>provide a current margin at the service of the barrier and all its compensations,<\/strong> due to misalignment, eddy light sources, etc.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Last but not least, citing the reference standard UNI 9795, we recall that the maximum coverage of a linear smoke barrier is equivalent to a single fire zone and therefore no more than 1600 square metres.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This means that each barrier must have its own dedicated power box, as in the event of a fault it is not allowed to lose more than one fire zone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, by using the barriers on loops <strong>it is necessary to pay close attention to the amount of them on the single loop and to the division into zones of the system itself<\/strong>, moreover without security that the system holds.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-b890746c gb-headline-text\"><strong><strong>For these reasons, we can definitively say that the barriers powered by loops, despite their technical goodness, are not the best solution in a smoke detection system.<\/strong><\/strong><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-7e060bd4 gb-headline-text\">As fire specialists, we know that the most appropriate solution you can use is the <strong>24V powered linear smoke barriers that you can find in our FireFocus range: Reflection Linear Barriers and TX-RX Linear Barriers.<\/strong><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-2884ac1c gb-headline-text\"><strong><strong><strong>Thanks to our linear barriers powered at 24V, you will be sure not to have failures on the loop such as to create disruptions and you will be able to avoid the complicated calculations of electrical margins, which are instead necessary in the case of barriers powered on loops.<\/strong><\/strong><\/strong><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-52cbaef6 gb-headline-text\">The linear smoke barriers powered at 24V of the FireFocus range<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"gb-headline gb-headline-40bd8d8c gb-headline-text\"><strong>Reflective Smoke Linear Barrier<\/strong><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"gb-container gb-container-0304c33a\">\n\n<ul class=\"wp-block-list\">\n<li><strong>reflective smoke linear barrier, infrared<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>consisting of 1 transmitter-receiver unit and 1 prism reflector<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>capacity 8-100m, with self calibration<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>suitable for industrial premises<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>optical filter for testing and alignment<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>certified EN54-12 CPD<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<\/div>\n\n\n<p class=\"gb-headline gb-headline-74b7fa7d gb-headline-text\"><strong><strong>TX-RX linear smoke barrier<\/strong><\/strong><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"gb-container gb-container-05cf0c85\">\n\n<ul class=\"wp-block-list\">\n<li><strong>linear infrared smoke barrier consisting of a transmitter and a receiver<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>flow rate 5-100m<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>RS-485 connection<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>1 alarm relay output<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>1 fault relay output<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>certified EN54-12 CPD, VdS<\/strong><\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/firefocus.it\/en\/all-products\/\" target=\"_blank\" rel=\"noreferrer noopener\">Go to products<\/a><\/div>\n<\/div>\n\n<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>The issue of the use of linear barriers within a fire smoke detection system&#8230;<\/p>\n","protected":false},"author":1,"featured_media":3201,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[32],"tags":[],"class_list":["post-3176","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-non-categorizzato"],"acf":[],"_links":{"self":[{"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/posts\/3176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/comments?post=3176"}],"version-history":[{"count":3,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/posts\/3176\/revisions"}],"predecessor-version":[{"id":3194,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/posts\/3176\/revisions\/3194"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/media\/3201"}],"wp:attachment":[{"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/media?parent=3176"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/categories?post=3176"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/firefocus.it\/en\/wp-json\/wp\/v2\/tags?post=3176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}